| Ultra-low-loss G.652 (ULL) | ≤0.17 @1550 · ≤0.20 @1625 | Disp. ≤18 ps/(nm·km) @1550 · PMD ≤0.1 ps/√km | Ethernet, IP, ATM, SONET and WDM systems; ribbon, loose-tube, slotted-core and tight-buffered constructions |
| G.652.D | ≤0.21 @1550 · ≤0.24 @1625 | ZDW 1300–1324 nm · PMD ≤0.2 ps/√km | Long-haul trunk, metropolitan, access and large-enterprise networks |
| G.654.E | ≤0.17 @1550 · ≤0.20 @1625 | Effective area 130 µm² typ. · λcc ≤1520 nm | High launch-power links; suppression of stimulated Brillouin scattering and nonlinear effects |
| G.655.C/D | ≤0.22 @1550 · ≤0.24 @1625 | Disp. 2.0–6.0 ps/(nm·km) @1530–1565 nm | C- and L-band multichannel DWDM; high-output-power EDFA systems |
| G.657.A1 | ≤0.22 @1550 | Macrobend 10 turns Ø30 mm ≤0.25 dB | Short-reach cable and high-speed FTTx routing across O, S, C and L bands |
| G.657.A2 | ≤0.22 @1550 | Macrobend 10 turns Ø30 mm ≤0.03 dB | FTTx routing where tight bends and small enclosures are unavoidable |
| G.657.B3 | ≤0.21 @1550 | Macrobend 1 turn Ø10 mm ≤0.15 dB | Premises and access runs with the tightest bend requirements |
| OM1 62.5/125 µm | ≤2.9 @850 · ≤0.7 @1300 | OFL bandwidth ≥200 MHz·km · NA 0.275 | Video, voice and data in LANs; Gigabit Ethernet with laser or LED sources |
| OM2 50/125 µm | ≤2.5 @850 · ≤0.8 @1300 | OFL bandwidth ≥500 MHz·km · NA 0.20 | Lower-bit-rate systems using conventional LED sources |
| OM3 50/125 µm | ≤2.5 @850 · ≤0.8 @1300 | OFL ≥1500 MHz·km · EMB ≥2000 MHz·km | High-speed LANs and lower-bit-rate systems including FDDI, Ethernet and ATM |
| OM4 50/125 µm | ≤2.5 @850 · ≤0.8 @1300 | OFL ≥3500 MHz·km · EMB ≥4700 MHz·km | Data centres, financial centres and enterprise campuses |
| OM5 50/125 µm wideband | ≤2.5 @850 · ≤1.8 @953 | OFL ≥3500 @850 / ≥1850 @953 MHz·km | 100/400G Ethernet in data centres; 16/32G Fibre Channel |